A B C D E F G H I J K L M N O P Q R S T U V W X Y Z All
Vishnukumar, S.
- An Efficient Recycling of Leakage Energies in Interleaved DC-DC Converter
Authors
1 Department of Instrumentation & Control Engg, Tamilnadu College of Engineering, Coimbatore-21, IN
Source
Programmable Device Circuits and Systems, Vol 8, No 5 (2016), Pagination: 124-129Abstract
In order to improve the efficiency of DC–DC converter common active clamp boost circuit is used. This can be achieved by interleaving the coupled-inductor boost converters. The Clamp boost converter is used to clamp the voltage stresses of all the switches in the interleaved converters, caused by the leakage inductances present in the practical coupled inductors, to a low voltage level by use of PID controller. The leakage energies of the interleaved converters are collected in a clamp capacitor and recycled to the output by the clamp boost converter controlled by the PID controller. The proposed converter achieves high efficiency because of the recycling of the leakage energies, reduction of the switch voltage stress, and reduction of the output diode’s reverse recovery problem. Detailed analysis and design of the proposed converter are carried out. The effectiveness of the control strategies have been verified by simulation results.
- Power Quality in a Smart Grid Distribution System
Authors
1 Tamilnadu College of Engineering, IN
Source
Programmable Device Circuits and Systems, Vol 9, No 7 (2017), Pagination: 159-163Abstract
The main criteria required for all the electrical and electronic device is the voltage. It plays vital role in a power quality. It is planned to provide a transformer with multiple taps and selecting the taps required for the moment will be automatically selected by the on-load changeover system which is operated by the controller. Computer acts as a controller with the aid of the C software. Voltage transducers are used to sense the voltage and ADC to convert into digital signals. These digital signals arte interfaced with computer which in turns operates the On Load Tap Changers (OLTC). Suitable taps are selected and its drive relays are operated by the computer through opto-coupler and switching transistors.Keywords
ADC, OLTC, Opto-Coupler, Switching Transducer.References
- MohdKhairunNizamMohd Sarmin1, Worawat Nakawiro1, MohdZamriChe Wanik2, MohdFadzilMohd Siam1, ZahrulFaiziHussien1, Ahmad Asrul Ibrahim3, Ahmad Kamil Mat Hussin - Coordinated Voltage Control in Distribution Network with Renewable Energy Based Distributed GenerationEngineering, 2013, 5, 208-214 Published Online January 2013.
- Jesus Cardenas, Leopoldo A. Gemoets, Jose H. Ablanedo Rosas, Robert SarfiJournal of Cleaner Production (Impact Factor: 3.84). 02/2014; 65:202–216. DOI: 10.1016
- Han, Y.; Song, Y. H. Condition Monitoring Techniques for Electrical Equipment: A Literature Survey, Power Engineering Review, IEEE, Year: 2002, Volume: 22, Issue: 9, Pages: 59 - 59, DOI: 10.1109/MPER.2002.4312590, Cited by: Papers , IEEE Journals & Magazines
- Non-invasive on-line condition monitoring of on load tap changers, Pengju Kang; Birtwhistle, D.; Daley, J.; McCulloch, D.Power Engineering Society Winter Meeting, 2000. IEEE, Year: 2000, Volume: 3, Pages: 2223 – 2228, vol.3, DOI: 10.1109/PESW.2000.847701, Cited by: Papers (10), IEEE Conference Publications
- K. Bhattacharya, M. H. J. Bollen, and J. E. Daalder, Operation of Restructured Power Systems.: Kluwer’s Power Electronics and Power Systems Series, 2001.
- Dieter Dohnal, “On-Load Tap-Changers for Power Transformers”, A Technical Digest, MR Publication, (2004).
- F. Dong, B. H. Chowdhury, M. L. Crow, and L. Acar, "Mid-term voltage stability study using the quasi-steady state analysis method," in IEEE PES General Meeting, Toronto, 2003, pp. 2646-2651.
- Taylor, C.W.: "Power System Voltage Stability", McGraw-Hill, 1993.
- Taylor, C.W.: "Concepts of Undervoltage Load Shedding for Voltage Stability", IEEE Transactions on Power Delivery, vol. 7, no. 2, pp. 480-488, April 1992.
- Ingelsson, Karlsson, Lindstrˆm, Runvik and Sjˆdin: ìSpecial Protection Scheme against Voltage Collapse in the South Part of the Swedish Gridî, 1996 CIGRE Conference in Paris.
- Mats Larsson: ìCoordinated Voltage Control in Electrical Power Systemsî, , Dissertation, Lund University, Sweden, December 2000.
- Daniel Karlsson: ìVoltage Stability Simulations Using Detailed Models Based on Field Measurementsî, PhD Dissertation, Chalmers University, Sweden, 1992
- "Elavbrottet 23 september, 2003 (Blackout 23 September, 2003)", Report Nr 1:2003, SenskaKraftn‰t, 2003-11-03, available on www.svk.se.
- "Application Manual for Power Transformer Protection and Control Terminal", ABB Document: 1MRK504037-UEN.
- Dr. Dieter Dohnal, “on-load Tap-changers for Power Transformers”, MR knowledge base, MaschinenfabrikReinhausen GmbH in Regensburg, Germany, www.reinhausen.com (2013).
- Hans Linder, “On-load Tap Changer, Type UC, Technical Guide”, Power and productivity, ABB AB Components, SE-771 80 LUDVIKA, Sweden,(2012).